Cell & Battery Test Solutions · Lead Test & Formation · Laboratory · Module SLI Tester
DCA Tester
Dynamic Charge Acceptance (DCA), standardized in EN 50342-6, measures how well a micro-hybrid vehicle battery accepts load pulses during recuperation. Although standardized, the procedure is complicated — with IF/THEN/ELSE branching and a total testing time of up to two weeks. Ador Digatron supports OEMs and battery manufacturers by offering a DCA testing package that manages the effort and complexity.
All-In-One DCA Solution
Purpose-built for dynamic charge acceptance testing of lead batteries per EN 50342-6.
Managed Complexity
Automates branching test sequences and long-duration test schedules.
Technical Data
| Voltage range | -20 V up to 20 V |
|---|---|
| Paralleling of circuits | Yes |
| Control accuracy U DC | < ± 0.05 % fs |
| Control accuracy I DC | ± 0.1 % fs |
| Regenerative DC link | Yes |
| Mains feedback | Yes |
| Circuits per power module | 1 up to 6 |
| Max. circuits per cabinet | 48 |
| Scalable | Yes |
* additional values on request
Suitable for the Following Tests
Dynamic Charge Acceptance (EN 50342-6)Micro-hybrid load pulse simulation